System introduction

Stimulus and response recording with multiple simultaneous measurements
Signal is a sweep based data acquisition and analysis package. Its uses range from a simple storage oscilloscope to complex applications requiring stimulus generation, data capture, control of external equipment and custom analysis. This flexibility makes it ideal for a wide range of applications including transient capture, patch and voltage clamp, LTP studies and evoked response.
 
The powerful data capture and time-saving analysis functions of Signal together with one of the CED 1401 family of laboratory interfaces make an extremely flexible and cost effective addition to any laboratory.
 
Features

Automated action potential analysis
Acquisition
Typical applications and script-driven functions

Data capture with independent frame length per stimulus type

Evoked response and TMS Output fixed, random and pseudo-random pulse outputs with on-line and off-line waveform averages and measurements of latencies, amplitudes and areas. Auto-averaging enables the user to specify the last n frames to form an average and measurements can be taken automatically from the results. Signal can control Magstim transcranial magnetic stimulators during data acquisition, including adjusting stimulator amplitude and timing and checks on stimulator condition. Settings are stored with the corresponding data frame.
 
LTP / LTD Generate single, paired and trains of pulses on multiple outputs. Signal automatically measures baselines, amplitudes, latencies, areas, durations, percentage rise and decay times, and population spike parameters for single or multiple responses per frame.
 
Whole cell voltage and current clamp Interactively control holding potentials and pulse outputs using the graphical sequencer. Construct I/V plots, leak subtraction and curve fits on-line and off-line.
 
Single channel patch clamp Detect single and multi-level channel openings on-line and off-line automatically. Produce measurements such as open/closed times and amplitudes and display result histograms.
 
EMG Record single and multiple channels of EMG with software control of amplifiers such as the CED 1902. Perform rectification and smoothing at the touch of a button or under script control. Produce power spectra that update as new data sweeps are captured.
 
Transients Detect waveforms rising or falling below a threshold as a trigger. Capture peri-trigger data up to the available size of memory inside your CED 1401. Optionally output stimuli in response to the trigger.
 
Auditory evoked potentials Generate complex stimulus protocols and reports under script control. Features include: automatic artefact rejection, digital filtering, generation of sub and grand averages and feature detection using active cursors.

LTP analysis with tabulated results
 

Output pulse editor
 

Output states control
 

Single channel patch clamp analysis
Complex stimuli and experimental control
 
Signal generates a large range of output stimuli, with two methods available for specifying outputs. The graphical pulse editor covers the majority of stimulus requirements in an easy to use drag and drop environment where you build up to 256 sets of up to 500 pulses. Outputs are fixed or they can change amplitude and duration on repeats. You can also modify them while sampling continues.
 
If your requirements cannot be met with the pulse editor you can define your outputs as a text sequence of instructions. This makes it possible to control the sequence interactively through the script language by use of variables and tables.
 
The script language has further experimental control options including communication through serial lines, files and commands for starting and stopping other programs.
 
Advanced features
 
Multiple sampling conditions Signal includes a comprehensive multiple output states system that provides differing pulse outputs or stimuli while sampling. The order and repeats of each stimulus can be sequenced using a predefined protocol or executed semi-randomly or randomly. Each frame of data is marked to indicate the stimulus that was used.
 
Voltage and current clamp Signal generates all of the stimuli needed for voltage and current clamp protocols, including pre-recorded action potential waveforms. Multiple sets of stimuli can be stored in one sampling configuration and selected manually or automatically sequenced. Voltage stimuli levels are either relative to an adjustable holding potential or fixed. Automated on-line measurement of seal and membrane resistance can be made during recordings. Leak-subtraction and I/V plots are always available even while sampling. Curve fitting can be applied to raw waveform data, leak subtracted data and I/V plots.
 
Single channel patch clamp Signal produces idealised current traces from patch data showing detected transition events. The idealised trace is editable by dragging open/closed times and amplitudes; there are additional tools for splitting and combining events. Amplitude histograms from raw or idealised data and dwell time histograms from idealised traces are available. Derived histograms can be characterised by a number of fit types.
 
A special feature is the reverse convolution fitting of an amplifier's step response to filtered single channel patch clamp data allowing superior time resolution of events.
Script language
 
From complete beginners to experienced programmers, everybody can benefit from the built-in script language. Even simple automation of repetitive tasks with known parameters can save hours or even days of tedious analysis. Advanced scripts can provide complete experiment control with on-line application of original algorithms to sampled data in real-time.
 
The script language allows you to generate your own interface and design algorithms. There is a macro recording facility to provide a starting point for new scripts. The script language also includes data manipulation tools such as multi-dimensional arrays and matrix functions.
 
CED maintains a library of example scripts for a wide range of common and specialised applications. If the scripts included with the Signal software or those available from our web site do not fulfil your exact requirements, please contact us to discuss the available options. These include modification of existing scripts and a dedicated script-writing service.
 
Signal version 4 features
 

Control of muscle length with analysis of resultant tension slopes
 

Signal on-line help: Digital filtering

Hardware requirements
 
Signal version 4 requires a CED Micro1401, Power1401 or 1401plus intelligent laboratory interface and a PC with Windows 98SE, ME, NT 2000, XP, XP64 or Vista™. We recommend that the PC has a minimum of 1GB of RAM.
 
Signal can export data to other applications as text, binary or image files. The Signal data format (CFS) is freely available to programmers wishing to read and write Signal data files

Windows®, Magstim and Multiclamp are registered trademarks of their respective holders.
10/07 Spike2 Signal or Spike2? Patch clamp details Demo set Script library V3 Prices CED home page